Subject: Incorrect State of Charge (SOC) calculation for Citroën ë-C3 (Software 3.25.52)
Hello ABRP Team,
I found what appears to be an SOC calculation issue with my 2025 Citroën ë-C3 (44 kWh LFP).
Vehicle
Model: 2025 Citroën ë-C3
Infotainment Software: SW 3.25.52
OBD Adapter: Vgate iCar Pro 2S BLE
iPhone (latest iOS)
ABRP latest version
Problem
ABRP connects successfully to the vehicle and reads live data without connection errors.
However, the State of Charge (%) is incorrect, while the remaining battery energy (kWh) appears to be correct.
Example:
Vehicle dashboard: 85% SOC
Engineering/Service menu: 86.2% SOC
Remaining energy reported by the BMS: 33.984 kWh
Full usable energy reported by the BMS: 39.584 kWh
This is internally consistent:
33.984 / 39.584 = 85.85%
However, ABRP reports:
62.3% SOC
Remaining energy: 33.64 kWh
So ABRP reads the remaining energy correctly but calculates or interprets SOC incorrectly.
Additional Information
Vehicle started at 100% SOC
After approximately 55 km of driving, the dashboard shows 85%, which is consistent with the BMS values.
The issue seems to affect vehicles running software version 3.25.52.
Other owners with newer software versions may not experience this issue.
It appears that ABRP may be using an incorrect CAN signal or battery capacity for this software version.
If needed, I can provide screenshots of:
Dashboard SOC
Engineering menu
ABRP live data
OBD logs
Thank you for looking into this issue